Energy Performance Certificate

52, Arlington Road, LS8 2RU

EPC Report

Energy rating

Current: 51 E | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 58 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 86 Potential: 86
Field Value
LMK KEY 8505-6685-9229-1227-8633
ADDRESS1 52, Arlington Road
ADDRESS2
ADDRESS3
POSTCODE LS8 2RU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-06-28
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001321
COUNTY
LODGEMENT DATE 2017-06-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 288
ENERGY CONSUMPTION POTENTIAL 93
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 1614
HEATING COST POTENTIAL 532
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 70
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 70% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, Arlington Road
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds North East
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-06-29 14:41:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 72005678
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew