Energy Performance Certificate

4, Southey Close, LE4 6DT

EPC Report

Energy rating

Current: 72 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 95 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 95 Current: 95 95 Potential: 95
Field Value
LMK KEY 8499-7551-9629-1997-6973
ADDRESS1 4, Southey Close
ADDRESS2
ADDRESS3
POSTCODE LE4 6DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-11-15
LOCAL AUTHORITY E06000016
CONSTITUENCY E14001326
COUNTY
LODGEMENT DATE 2013-11-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 95
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 173
ENERGY CONSUMPTION POTENTIAL 165
CO2 EMISSIONS CURRENT 0.5
CO2 EMISS CURR PER FLOOR AREA 5
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 487
HEATING COST POTENTIAL 460
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Flat rate charging, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Flat rate charging, TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 85% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL biomass (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Southey Close
LOCAL AUTHORITY LABEL Leicester
CONSTITUENCY LABEL Leicester East
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2013-11-18 17:17:29
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 2465082628
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display
Nation ew