Energy Performance Certificate

74, Monnow Street, NP25 3EN

EPC Report

Energy rating

Current: 1 G | Potential: 16 G
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 16 G Potential: 16 G

Environmental impact (CO₂)

Current: 1 | Potential: 15
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 15 Potential: 15
Field Value
LMK KEY 8497-7024-0380-5760-5992
ADDRESS1 74, Monnow Street
ADDRESS2
ADDRESS3
POSTCODE NP25 3EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING G
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 16
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-04-10
LOCAL AUTHORITY W06000021
CONSTITUENCY W07000101
COUNTY
LODGEMENT DATE 2013-04-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 15
ENERGY CONSUMPTION CURRENT 939
ENERGY CONSUMPTION POTENTIAL 516
CO2 EMISSIONS CURRENT 34
CO2 EMISS CURR PER FLOOR AREA 183
CO2 EMISSIONS POTENTIAL 19
LIGHTING COST CURRENT 130
LIGHTING COST POTENTIAL 132
HEATING COST CURRENT 6473
HEATING COST POTENTIAL 3708
HOT WATER COST CURRENT 331
HOT WATER COST POTENTIAL 186
TOTAL FLOOR AREA 188
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 74, Monnow Street
LOCAL AUTHORITY LABEL Monmouthshire
CONSTITUENCY LABEL Monmouthshire
POSTTOWN MONMOUTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-04-10 16:30:52
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100100265353
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew