Energy Performance Certificate

173, Culverley Road, SE6 2JZ

EPC Report

Energy rating

Current: 42 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 33 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 60 Potential: 60
Field Value
LMK KEY 8496-7527-4020-5334-6922
ADDRESS1 173, Culverley Road
ADDRESS2
ADDRESS3
POSTCODE SE6 2JZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-03-24
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001331
COUNTY
LODGEMENT DATE 2016-03-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 330
ENERGY CONSUMPTION POTENTIAL 166
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 5.7
LIGHTING COST CURRENT 130
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 2139
HEATING COST POTENTIAL 1258
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 194
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 33
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.01
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 173, Culverley Road
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham East
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-03-25 10:18:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100021948306
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew