Energy Performance Certificate

34, Manse Avenue, Wrightington, WN6 9RP

EPC Report

Energy rating

Current: 40 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 33 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 75 Potential: 75
Field Value
LMK KEY 8495-5812-1629-5097-7063
ADDRESS1 34, Manse Avenue
ADDRESS2 Wrightington
ADDRESS3
POSTCODE WN6 9RP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-10-19
LOCAL AUTHORITY E07000127
CONSTITUENCY E14001577
COUNTY
LODGEMENT DATE 2016-10-25
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 450
ENERGY CONSUMPTION POTENTIAL 140
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1578
HEATING COST POTENTIAL 683
HOT WATER COST CURRENT 128
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 107
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34, Manse Avenue, Wrightington
LOCAL AUTHORITY LABEL West Lancashire
CONSTITUENCY LABEL West Lancashire
POSTTOWN WIGAN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-10-25 10:58:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100010692094
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew