Energy Performance Certificate

28, Claverton Estate, Stoulton, WR7 4RH

EPC Report

Energy rating

Current: 44 E | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 37 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 56 Potential: 56
Field Value
LMK KEY 8488-6625-8090-2415-1902
ADDRESS1 28, Claverton Estate
ADDRESS2 Stoulton
ADDRESS3
POSTCODE WR7 4RH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-05-05
LOCAL AUTHORITY E07000238
CONSTITUENCY E14001203
COUNTY
LODGEMENT DATE 2018-05-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 273
ENERGY CONSUMPTION POTENTIAL 156
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 910
HEATING COST POTENTIAL 691
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 109
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Claverton Estate, Stoulton
LOCAL AUTHORITY LABEL Wychavon
CONSTITUENCY LABEL Droitwich and Evesham
POSTTOWN WORCESTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-05-05 11:23:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10013940388
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000005
Address display
Nation ew