Energy Performance Certificate

74, Charles Street, CF40 2AW

EPC Report

Energy rating

Current: 29 F | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 28 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 84 Potential: 84
Field Value
LMK KEY 8485-6729-6389-8155-4902
ADDRESS1 74, Charles Street
ADDRESS2
ADDRESS3
POSTCODE CF40 2AW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-11-05
LOCAL AUTHORITY W06000016
CONSTITUENCY W07000107
COUNTY
LODGEMENT DATE 2015-11-13
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 645
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 7.8
CO2 EMISS CURR PER FLOOR AREA 113
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 1568
HEATING COST POTENTIAL 507
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 49
TOTAL FLOOR AREA 69
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 75
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 74, Charles Street
LOCAL AUTHORITY LABEL Rhondda Cynon Taf
CONSTITUENCY LABEL Rhondda and Ogmore
POSTTOWN TONYPANDY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-11-13 15:37:16
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100733153
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew