Energy Performance Certificate

3, Clifton Grove, Old Trafford, M16 7PG

EPC Report

Energy rating

Current: 50 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 47 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 62 Potential: 62
Field Value
LMK KEY 8481-6221-4860-0346-2926
ADDRESS1 3, Clifton Grove
ADDRESS2 Old Trafford
ADDRESS3
POSTCODE M16 7PG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-09-26
LOCAL AUTHORITY E08000009
CONSTITUENCY E14001528
COUNTY
LODGEMENT DATE 2019-09-26
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 363
ENERGY CONSUMPTION POTENTIAL 247
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 868
HEATING COST POTENTIAL 557
HOT WATER COST CURRENT 251
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 70
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Clifton Grove, Old Trafford
LOCAL AUTHORITY LABEL Trafford
CONSTITUENCY LABEL Stretford and Urmston
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-09-26 16:32:27
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100011651899
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000002
Address display
Nation ew