Energy Performance Certificate

13a, Lyndhurst Road, EX2 4PA

EPC Report

Energy rating

Current: 64 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 54 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 70 Potential: 70
Field Value
LMK KEY 8478-7124-5240-5566-1992
ADDRESS1 13a, Lyndhurst Road
ADDRESS2
ADDRESS3
POSTCODE EX2 4PA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-04-16
LOCAL AUTHORITY E07000041
CONSTITUENCY E14001231
COUNTY
LODGEMENT DATE 2018-04-16
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 189
ENERGY CONSUMPTION POTENTIAL 117
CO2 EMISSIONS CURRENT 11.4
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 7.1
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 138
HEATING COST CURRENT 2007
HEATING COST POTENTIAL 1395
HOT WATER COST CURRENT 138
HOT WATER COST POTENTIAL 138
TOTAL FLOOR AREA 332
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 14
NUMBER HEATED ROOMS 14
LOW ENERGY LIGHTING 95
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 95% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13a, Lyndhurst Road
LOCAL AUTHORITY LABEL Exeter
CONSTITUENCY LABEL Exeter
POSTTOWN EXETER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-04-16 16:42:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 100040222541
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew