Energy Performance Certificate

5, Romney Close, PE27 3HB

EPC Report

Energy rating

Current: 64 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 57 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 84 Potential: 84
Field Value
LMK KEY 8475-7827-3040-9042-9996
ADDRESS1 5, Romney Close
ADDRESS2
ADDRESS3
POSTCODE PE27 3HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-03-12
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001298
COUNTY
LODGEMENT DATE 2015-03-12
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 239
ENERGY CONSUMPTION POTENTIAL 79
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 770
HEATING COST POTENTIAL 486
HOT WATER COST CURRENT 181
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 110
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 59
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 59% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Romney Close
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL Huntingdon
POSTTOWN ST. IVES
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-03-12 15:39:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100090115696
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew