Energy Performance Certificate

2, Old Meadows Walk, SP2 8PA

EPC Report

Energy rating

Current: 31 F | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 17 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 47 Potential: 47
Field Value
LMK KEY 8466-7129-4630-7251-8926
ADDRESS1 2, Old Meadows Walk
ADDRESS2
ADDRESS3
POSTCODE SP2 8PA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-01-29
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001460
COUNTY
LODGEMENT DATE 2016-02-02
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 677
ENERGY CONSUMPTION POTENTIAL 315
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 115
CO2 EMISSIONS POTENTIAL 5.3
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 1468
HEATING COST POTENTIAL 876
HOT WATER COST CURRENT 483
HOT WATER COST POTENTIAL 159
TOTAL FLOOR AREA 100
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Warm air, Electricaire
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Old Meadows Walk
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Salisbury
POSTTOWN SALISBURY
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-02-02 16:14:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100121051378
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000009
Address display
Nation ew