Energy Performance Certificate

124, Westfield Road, BD9 5EQ

EPC Report

Energy rating

Current: 1 G | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 15 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 Current: 15 81 Potential: 81
Field Value
LMK KEY 8463-6227-4040-2768-6922
ADDRESS1 124, Westfield Road
ADDRESS2
ADDRESS3
POSTCODE BD9 5EQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-03-28
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001120
COUNTY
LODGEMENT DATE 2017-03-28
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 15
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 796
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 135
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 3080
HEATING COST POTENTIAL 538
HOT WATER COST CURRENT 541
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 124, Westfield Road
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Bradford West
POSTTOWN BRADFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-03-28 23:47:35
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100051234865
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew