Energy Performance Certificate

28, Preston on Stour, CV37 8NG

EPC Report

Energy rating

Current: 45 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 25 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 69 Potential: 69
Field Value
LMK KEY 8461-7220-6899-2738-7992
ADDRESS1 28
ADDRESS2 Preston on Stour
ADDRESS3
POSTCODE CV37 8NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-10-18
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001526
COUNTY
LODGEMENT DATE 2019-11-18
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 648
ENERGY CONSUMPTION POTENTIAL 202
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 114
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 1007
HEATING COST POTENTIAL 425
HOT WATER COST CURRENT 215
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 65
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Preston on Stour
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Stratford-on-Avon
POSTTOWN STRATFORD-UPON-AVON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-11-18 12:44:17
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10023587985
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000005
Address display
Nation ew