Energy Performance Certificate

Flat 3, 35, Farnham Road, GU2 4JN

EPC Report

Energy rating

Current: 41 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 24 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 58 Potential: 58
Field Value
LMK KEY 8448-7929-1069-2769-2926
ADDRESS1 Flat 3
ADDRESS2 35, Farnham Road
ADDRESS3
POSTCODE GU2 4JN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2018-11-21
LOCAL AUTHORITY E07000209
CONSTITUENCY E14001258
COUNTY
LODGEMENT DATE 2018-11-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 700
ENERGY CONSUMPTION POTENTIAL 298
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 118
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 1033
HEATING COST POTENTIAL 317
HOT WATER COST CURRENT 158
HOT WATER COST POTENTIAL 158
TOTAL FLOOR AREA 60
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.26
FLOOR HEIGHT 2.625
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3, 35, Farnham Road
LOCAL AUTHORITY LABEL Guildford
CONSTITUENCY LABEL Guildford
POSTTOWN GUILDFORD
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-11-21 17:37:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100062130653
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew