Energy Performance Certificate

HOWARDS CORNER, THE COTTONS, OUTWELL, PE14 8TP

EPC Report

Energy rating

Current: 33 F | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 29 | Potential: 48
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 48 Potential: 48
Field Value
LMK KEY 8439-1325-3000-0334-6292
ADDRESS1 HOWARDS CORNER
ADDRESS2 THE COTTONS
ADDRESS3 OUTWELL
POSTCODE PE14 8TP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-05-14
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001497
COUNTY
LODGEMENT DATE 2021-05-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 48
ENERGY CONSUMPTION CURRENT 290
ENERGY CONSUMPTION POTENTIAL 170
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 9.3
LIGHTING COST CURRENT 140
LIGHTING COST POTENTIAL 140
HEATING COST CURRENT 2242
HEATING COST POTENTIAL 1519
HOT WATER COST CURRENT 147
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 205
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 93% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS HOWARDS CORNER, THE COTTONS, OUTWELL
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL South West Norfolk
POSTTOWN OUTWELL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-05-14 16:31:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10000049453
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew