Energy Performance Certificate

Glencoe, Oakwood Road, Sling, GL16 8JG

EPC Report

Energy rating

Current: 31 F | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 30 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 77 Potential: 77
Field Value
LMK KEY 8435-7124-3020-0540-6992
ADDRESS1 Glencoe
ADDRESS2 Oakwood Road
ADDRESS3 Sling
POSTCODE GL16 8JG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-04-10
LOCAL AUTHORITY E07000080
CONSTITUENCY E14001240
COUNTY
LODGEMENT DATE 2015-04-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 592
ENERGY CONSUMPTION POTENTIAL 175
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 98
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 98
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1631
HEATING COST POTENTIAL 735
HOT WATER COST CURRENT 194
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 86
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas range cooker
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Glencoe, Oakwood Road, Sling
LOCAL AUTHORITY LABEL Forest of Dean
CONSTITUENCY LABEL Forest of Dean
POSTTOWN COLEFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-04-13 08:17:53
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 200002914613
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew