Energy Performance Certificate

199, Ladysmith Road, PL4 7NR

EPC Report

Energy rating

Current: 15 G | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 G Current: 15 G 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 26 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 74 Potential: 74
Field Value
LMK KEY 8411-7627-6580-5366-0922
ADDRESS1 199, Ladysmith Road
ADDRESS2
ADDRESS3
POSTCODE PL4 7NR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 15
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-03-26
LOCAL AUTHORITY E06000026
CONSTITUENCY E14001427
COUNTY
LODGEMENT DATE 2019-03-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 554
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 95
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 1988
HEATING COST POTENTIAL 489
HOT WATER COST CURRENT 90
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.24
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 199, Ladysmith Road
LOCAL AUTHORITY LABEL Plymouth
CONSTITUENCY LABEL Plymouth Sutton and Devonport
POSTTOWN PLYMOUTH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2019-03-29 07:56:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100040456886
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew