Energy Performance Certificate

282, Uttoxeter Road, Blythe Bridge, ST11 9LY

EPC Report

Energy rating

Current: 55 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 53 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 75 Potential: 75
Field Value
LMK KEY 8409-5573-2229-7627-8263
ADDRESS1 282, Uttoxeter Road
ADDRESS2 Blythe Bridge
ADDRESS3
POSTCODE ST11 9LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-02-23
LOCAL AUTHORITY E07000198
CONSTITUENCY E14001522
COUNTY
LODGEMENT DATE 2016-02-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 377
ENERGY CONSUMPTION POTENTIAL 198
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 824
HEATING COST POTENTIAL 666
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 61
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 282, Uttoxeter Road, Blythe Bridge
LOCAL AUTHORITY LABEL Staffordshire Moorlands
CONSTITUENCY LABEL Stoke-on-Trent South
POSTTOWN STOKE-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-02-23 13:20:17
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100031863497
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew