Energy Performance Certificate

Flat 3, 190b Lavender Hill, SW11 5TQ

EPC Report

Energy rating

Current: 75 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 78 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 79 Potential: 79
Field Value
LMK KEY 8409-5446-0922-3927-4203
ADDRESS1 Flat 3
ADDRESS2 190b Lavender Hill
ADDRESS3
POSTCODE SW11 5TQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-02-24
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001081
COUNTY
LODGEMENT DATE 2020-03-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 126
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 315
HEATING COST POTENTIAL 315
HOT WATER COST CURRENT 282
HOT WATER COST POTENTIAL 245
TOTAL FLOOR AREA 90
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 0.9
FLOOR HEIGHT 2.629
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3, 190b Lavender Hill
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Battersea
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2020-03-10 16:59:03
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000007
Address display
Nation ew