Energy Performance Certificate

8, Lynden Close, East Grafton, SN8 3US

EPC Report

Energy rating

Current: 46 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 37 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 58 Potential: 58
Field Value
LMK KEY 8409-3453-4129-3707-4953
ADDRESS1 8, Lynden Close
ADDRESS2 East Grafton
ADDRESS3
POSTCODE SN8 3US
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-01-05
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001217
COUNTY
LODGEMENT DATE 2015-03-20
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 529
ENERGY CONSUMPTION POTENTIAL 314
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 786
HEATING COST POTENTIAL 682
HOT WATER COST CURRENT 303
HOT WATER COST POTENTIAL 125
TOTAL FLOOR AREA 63
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.372
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Lynden Close, East Grafton
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL East Wiltshire
POSTTOWN MARLBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2015-03-20 14:37:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100120983521
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew