Energy Performance Certificate

4, Woolacombe Avenue, Sutton Leach, WA9 4NQ

EPC Report

Energy rating

Current: 54 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 47 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 78 Potential: 78
Field Value
LMK KEY 8408-4207-3522-4196-6903
ADDRESS1 4, Woolacombe Avenue
ADDRESS2 Sutton Leach
ADDRESS3
POSTCODE WA9 4NQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2020-01-10
LOCAL AUTHORITY E08000013
CONSTITUENCY E14001510
COUNTY
LODGEMENT DATE 2020-01-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 370
ENERGY CONSUMPTION POTENTIAL 142
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 772
HEATING COST POTENTIAL 493
HOT WATER COST CURRENT 91
HOT WATER COST POTENTIAL 62
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.19
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Woolacombe Avenue, Sutton Leach
LOCAL AUTHORITY LABEL St. Helens
CONSTITUENCY LABEL St Helens South and Whiston
POSTTOWN ST. HELENS
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-01-10 15:48:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 39065192
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew