Energy Performance Certificate

5, The Gregory, Leen Court, NG7 2HT

EPC Report

Energy rating

Current: 79 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 69 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 71 Potential: 71
Field Value
LMK KEY 8407-7521-1710-3366-2902
ADDRESS1 5, The Gregory
ADDRESS2 Leen Court
ADDRESS3
POSTCODE NG7 2HT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-09-06
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001412
COUNTY
LODGEMENT DATE 2013-09-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 256
ENERGY CONSUMPTION POTENTIAL 243
CO2 EMISSIONS CURRENT
CO2 EMISS CURR PER FLOOR AREA
CO2 EMISSIONS POTENTIAL
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 173
HEATING COST POTENTIAL 155
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 115
TOTAL FLOOR AREA 46
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 80
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 1.3
FLOOR HEIGHT 2.76
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, The Gregory, Leen Court
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham South
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2013-09-06 11:23:08
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 200001385223
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display
Nation ew