Energy Performance Certificate
7, Tregunter Road, SW10 9LS
Energy rating
Current: 67 D | Potential: 71 C
Environmental impact (CO₂)
Current: 55
| Potential: 60
| Field | Value |
|---|---|
| LMK KEY | 8407-5395-1629-0906-0513 |
| ADDRESS1 | 7, Tregunter Road |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | SW10 9LS |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 67 |
| POTENTIAL ENERGY EFFICIENCY | 71 |
| PROPERTY TYPE | House |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2019-05-01 |
| LOCAL AUTHORITY | E09000020 |
| CONSTITUENCY | E14001160 |
| COUNTY | — |
| LODGEMENT DATE | 2019-05-03 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 55 |
| ENVIRONMENT IMPACT POTENTIAL | 60 |
| ENERGY CONSUMPTION CURRENT | 155 |
| ENERGY CONSUMPTION POTENTIAL | 138 |
| CO2 EMISSIONS CURRENT | 20 |
| CO2 EMISS CURR PER FLOOR AREA | 27 |
| CO2 EMISSIONS POTENTIAL | 18 |
| LIGHTING COST CURRENT | 232 |
| LIGHTING COST POTENTIAL | 234 |
| HEATING COST CURRENT | 3478 |
| HEATING COST POTENTIAL | 3261 |
| HOT WATER COST CURRENT | 149 |
| HOT WATER COST POTENTIAL | 149 |
| TOTAL FLOOR AREA | 731 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 50 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | Less Than Typical |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 12 |
| NUMBER HEATED ROOMS | 12 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 2 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, limited insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Partial double glazing |
| WINDOWS ENERGY EFF | Poor |
| WINDOWS ENV EFF | Poor |
| WALLS DESCRIPTION | Solid brick, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Flat, insulated (assumed) |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas, Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 1.5 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 7, Tregunter Road |
| LOCAL AUTHORITY LABEL | Kensington and Chelsea |
| CONSTITUENCY LABEL | Chelsea and Fulham |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | I |
| LODGEMENT DATETIME | 2019-05-03 16:40:54 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 70 |
| LOW ENERGY FIXED LIGHT COUNT | 70 |
| UPRN | 217087654 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2019.csv |
| COUNTRY | England |
| REGION | E12000007 |
| Address display | — |
| Nation | ew |