Energy Performance Certificate

61a, Fen Street, Old Buckenham, NR17 1SR

EPC Report

Energy rating

Current: 19 G | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 G Current: 19 G 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 17 | Potential: 48
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 48 Potential: 48
Field Value
LMK KEY 8406-4663-3129-6427-9953
ADDRESS1 61a, Fen Street
ADDRESS2 Old Buckenham
ADDRESS3
POSTCODE NR17 1SR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 19
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-01-26
LOCAL AUTHORITY E07000143
CONSTITUENCY E14001365
COUNTY
LODGEMENT DATE 2015-01-26
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 48
ENERGY CONSUMPTION CURRENT 547
ENERGY CONSUMPTION POTENTIAL 227
CO2 EMISSIONS CURRENT 8.8
CO2 EMISS CURR PER FLOOR AREA 142
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 1463
HEATING COST POTENTIAL 780
HOT WATER COST CURRENT 215
HOT WATER COST POTENTIAL 183
TOTAL FLOOR AREA 62
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 61a, Fen Street, Old Buckenham
LOCAL AUTHORITY LABEL Breckland
CONSTITUENCY LABEL Mid Norfolk
POSTTOWN ATTLEBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-01-26 18:34:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10011972812
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew