Energy Performance Certificate

29a, Bratton Road, West Ashton, BA14 6AZ

EPC Report

Energy rating

Current: 60 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 51 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 66 Potential: 66
Field Value
LMK KEY 8404-4386-3429-5707-7513
ADDRESS1 29a, Bratton Road
ADDRESS2 West Ashton
ADDRESS3
POSTCODE BA14 6AZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-05-08
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001498
COUNTY
LODGEMENT DATE 2019-05-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 162
ENERGY CONSUMPTION POTENTIAL 98
CO2 EMISSIONS CURRENT 8.0
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 5.3
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 136
HEATING COST CURRENT 811
HEATING COST POTENTIAL 746
HOT WATER COST CURRENT 250
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 189
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29a, Bratton Road, West Ashton
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL South West Wiltshire
POSTTOWN TROWBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-05-08 18:49:37
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100121110069
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew