Energy Performance Certificate

11, Y Werddon, Pentrefelin, LL13 7LT

EPC Report

Energy rating

Current: 80 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 79 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 83 Potential: 83
Field Value
LMK KEY 8403-5886-6629-3597-3113
ADDRESS1 11, Y Werddon
ADDRESS2 Pentrefelin
ADDRESS3
POSTCODE LL13 7LT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-09-18
LOCAL AUTHORITY W06000006
CONSTITUENCY W07000111
COUNTY
LODGEMENT DATE 2019-09-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 208
ENERGY CONSUMPTION POTENTIAL 168
CO2 EMISSIONS CURRENT 1.2
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 33
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 136
HEATING COST POTENTIAL 86
HOT WATER COST CURRENT 176
HOT WATER COST POTENTIAL 176
TOTAL FLOOR AREA 34
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 2.6
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Y Werddon, Pentrefelin
LOCAL AUTHORITY LABEL Wrexham
CONSTITUENCY LABEL Wrexham
POSTTOWN WREXHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-09-24 18:49:47
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10013546988
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew