Energy Performance Certificate

10, Tern Grove, Loggerheads, TF9 4DZ

EPC Report

Energy rating

Current: 65 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 61 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 80 Potential: 80
Field Value
LMK KEY 8403-1390-3129-5677-2823
ADDRESS1 10, Tern Grove
ADDRESS2 Loggerheads
ADDRESS3
POSTCODE TF9 4DZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-08-31
LOCAL AUTHORITY E07000195
CONSTITUENCY E14001513
COUNTY
LODGEMENT DATE 2012-08-31
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 200
ENERGY CONSUMPTION POTENTIAL 96
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 110
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 784
HEATING COST POTENTIAL 622
HOT WATER COST CURRENT 112
HOT WATER COST POTENTIAL 92
TOTAL FLOOR AREA 128
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 23
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 23% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, Tern Grove, Loggerheads
LOCAL AUTHORITY LABEL Newcastle-under-Lyme
CONSTITUENCY LABEL Stafford
POSTTOWN MARKET DRAYTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2012-08-31 15:58:53
TENURE
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100031716439
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000005
Address display
Nation ew