Energy Performance Certificate
Flat 153 Fitzwarren Court, Rosehill Close, M6 5NF
Energy rating
Current: 52 E | Potential: 52 E
Environmental impact (CO₂)
Current: 33
| Potential: 33
| Field | Value |
|---|---|
| LMK KEY | 8401-6434-5390-4875-6902 |
| ADDRESS1 | Flat 153 Fitzwarren Court |
| ADDRESS2 | Rosehill Close |
| ADDRESS3 | — |
| POSTCODE | M6 5NF |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | E |
| CURRENT ENERGY EFFICIENCY | 52 |
| POTENTIAL ENERGY EFFICIENCY | 52 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2019-04-05 |
| LOCAL AUTHORITY | E08000006 |
| CONSTITUENCY | E14001459 |
| COUNTY | — |
| LODGEMENT DATE | 2019-04-05 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 33 |
| ENVIRONMENT IMPACT POTENTIAL | 33 |
| ENERGY CONSUMPTION CURRENT | 604 |
| ENERGY CONSUMPTION POTENTIAL | 604 |
| CO2 EMISSIONS CURRENT | 5.0 |
| CO2 EMISS CURR PER FLOOR AREA | 102 |
| CO2 EMISSIONS POTENTIAL | 5.0 |
| LIGHTING COST CURRENT | 56 |
| LIGHTING COST POTENTIAL | 56 |
| HEATING COST CURRENT | 749 |
| HEATING COST POTENTIAL | 749 |
| HOT WATER COST CURRENT | 158 |
| HOT WATER COST POTENTIAL | 158 |
| TOTAL FLOOR AREA | 49 |
| ENERGY TARIFF | off-peak 7 hour |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | 2 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Manual charge control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 83 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | (other premises below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Average thermal transmittance 1.88 W/m²K |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (other premises above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 83% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | Electricity: electricity, unspecified tariff |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.32 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | Flat 153 Fitzwarren Court, Rosehill Close |
| LOCAL AUTHORITY LABEL | Salford |
| CONSTITUENCY LABEL | Salford |
| POSTTOWN | SALFORD |
| CONSTRUCTION AGE BAND | 1968 |
| LODGEMENT DATETIME | 2019-04-05 02:23:52 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| UPRN | 100012718755 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 3 |
| Source file | certificates-2019.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |