Energy Performance Certificate

Larch Lodge, Unthank Farm, Skelton, CA11 9TG

EPC Report

Energy rating

Current: 63 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 75 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 89 Potential: 89
Field Value
LMK KEY 8400-4684-7139-4107-6963
ADDRESS1 Larch Lodge
ADDRESS2 Unthank Farm
ADDRESS3 Skelton
POSTCODE CA11 9TG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-01-08
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2016-01-08
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 177
ENERGY CONSUMPTION POTENTIAL 72
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 593
HEATING COST POTENTIAL 598
HOT WATER COST CURRENT 177
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 61
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 53
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.13 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.13 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.13 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 53% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: bulk LPG
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.1
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Larch Lodge, Unthank Farm, Skelton
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN PENRITH
CONSTRUCTION AGE BAND 2010
LODGEMENT DATETIME 2016-01-08 14:40:24
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10070540273
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew