Energy Performance Certificate

Flat 118, 77, Granby Row, M1 7BF

EPC Report

Energy rating

Current: 58 D | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 68 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 68 Potential: 68
Field Value
LMK KEY 8400-2185-7739-9727-7783
ADDRESS1 Flat 118
ADDRESS2 77, Granby Row
ADDRESS3
POSTCODE M1 7BF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2018-03-28
LOCAL AUTHORITY E08000003
CONSTITUENCY E14001352
COUNTY
LODGEMENT DATE 2018-03-28
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 306
ENERGY CONSUMPTION POTENTIAL 306
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 27
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 429
HEATING COST POTENTIAL 429
HOT WATER COST CURRENT 128
HOT WATER COST POTENTIAL 128
TOTAL FLOOR AREA 34
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.35 W/m²K
FLOOR ENERGY EFF Average
FLOOR ENV EFF Average
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.32 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, programmer and room thermostat
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 118, 77, Granby Row
LOCAL AUTHORITY LABEL Manchester
CONSTITUENCY LABEL Manchester Central
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2018-03-28 15:36:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10094088935
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew