Energy Performance Certificate

62 Radley House, 10, Palmer Road, SW11 4FS

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 86 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 86 Potential: 86
Field Value
LMK KEY 8395-8686-0739-5207-5913
ADDRESS1 62 Radley House
ADDRESS2 10, Palmer Road
ADDRESS3
POSTCODE SW11 4FS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2019-11-08
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001081
COUNTY
LODGEMENT DATE 2019-11-08
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 90
ENERGY CONSUMPTION POTENTIAL 90
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 181
HEATING COST POTENTIAL 181
HOT WATER COST CURRENT 88
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 69
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and at least two room stats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and at least two room stats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 62 Radley House, 10, Palmer Road
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Battersea
POSTTOWN LONDON
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2019-11-08 12:20:40
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10095438213
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2019.csv
COUNTRY England
REGION E12000007
Address display
Nation ew