Energy Performance Certificate

5 Border View, Beguildy, LD7 1YG

EPC Report

Energy rating

Current: 34 F | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 29 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 73 Potential: 73
Field Value
LMK KEY 8386-7529-0879-4528-2926
ADDRESS1 5 Border View
ADDRESS2 Beguildy
ADDRESS3
POSTCODE LD7 1YG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-11-28
LOCAL AUTHORITY W06000023
CONSTITUENCY W07000085
COUNTY
LODGEMENT DATE 2016-11-29
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 388
ENERGY CONSUMPTION POTENTIAL 73
CO2 EMISSIONS CURRENT 9.5
CO2 EMISS CURR PER FLOOR AREA 102
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1279
HEATING COST POTENTIAL 761
HOT WATER COST CURRENT 135
HOT WATER COST POTENTIAL 155
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Border View, Beguildy
LOCAL AUTHORITY LABEL Powys
CONSTITUENCY LABEL Brecon, Radnor and Cwm Tawe
POSTTOWN KNIGHTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-11-29 22:07:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10011773097
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew