Energy Performance Certificate

14, Denholme Drive, WF5 9NB

EPC Report

Energy rating

Current: 1 G | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 1 | Potential: 38
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 38 Potential: 38
Field Value
LMK KEY 8386-7321-4230-8587-6906
ADDRESS1 14, Denholme Drive
ADDRESS2
ADDRESS3
POSTCODE WF5 9NB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-09-03
LOCAL AUTHORITY E08000036
CONSTITUENCY E14001418
COUNTY
LODGEMENT DATE 2016-09-03
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 38
ENERGY CONSUMPTION CURRENT 1063
ENERGY CONSUMPTION POTENTIAL 206
CO2 EMISSIONS CURRENT 34
CO2 EMISS CURR PER FLOOR AREA 259
CO2 EMISSIONS POTENTIAL 9.1
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 4830
HEATING COST POTENTIAL 1218
HOT WATER COST CURRENT 554
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 132
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas, Room heaters, coal
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.9
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Denholme Drive
LOCAL AUTHORITY LABEL Wakefield
CONSTITUENCY LABEL Ossett and Denby Dale
POSTTOWN OSSETT
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-09-03 18:38:03
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 63030678
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew