Energy Performance Certificate
Flat 29, Collingwood Court, Stow Crescent, PO15 6FA
Energy rating
Current: 80 C | Potential: 80 C
Environmental impact (CO₂)
Current: 85
| Potential: 85
| Field | Value |
|---|---|
| LMK KEY | 8385-7635-3620-3544-3992 |
| ADDRESS1 | Flat 29 |
| ADDRESS2 | Collingwood Court |
| ADDRESS3 | Stow Crescent |
| POSTCODE | PO15 6FA |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 80 |
| POTENTIAL ENERGY EFFICIENCY | 80 |
| PROPERTY TYPE | Flat |
| BUILT FORM | — |
| INSPECTION DATE | 2015-05-14 |
| LOCAL AUTHORITY | E07000087 |
| CONSTITUENCY | E14001233 |
| COUNTY | — |
| LODGEMENT DATE | 2015-05-14 |
| TRANSACTION TYPE | New dwelling |
| ENVIRONMENT IMPACT CURRENT | 85 |
| ENVIRONMENT IMPACT POTENTIAL | 85 |
| ENERGY CONSUMPTION CURRENT | 105 |
| ENERGY CONSUMPTION POTENTIAL | 105 |
| CO2 EMISSIONS CURRENT | 1.0 |
| CO2 EMISS CURR PER FLOOR AREA | 18 |
| CO2 EMISSIONS POTENTIAL | 1.0 |
| LIGHTING COST CURRENT | 45 |
| LIGHTING COST POTENTIAL | 45 |
| HEATING COST CURRENT | 187 |
| HEATING COST POTENTIAL | 187 |
| HOT WATER COST CURRENT | 104 |
| HOT WATER COST POTENTIAL | 104 |
| TOTAL FLOOR AREA | 53 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | 3 |
| FLAT TOP STOREY | Y |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Flat rate charging, programmer and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 75 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.25 W/m²K |
| FLOOR ENERGY EFF | Good |
| FLOOR ENV EFF | Good |
| WINDOWS DESCRIPTION | High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| WALLS DESCRIPTION | Average thermal transmittance 0.22 W/m²K |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.14 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Flat rate charging, programmer and TRVs |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | — |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | Flat 29, Collingwood Court, Stow Crescent |
| LOCAL AUTHORITY LABEL | Fareham |
| CONSTITUENCY LABEL | Fareham and Waterlooville |
| POSTTOWN | FAREHAM |
| CONSTRUCTION AGE BAND | 2013 |
| LODGEMENT DATETIME | 2015-05-14 11:25:06 |
| TENURE | unknown |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 9 |
| UPRN | 10012138980 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 3 |
| Source file | certificates-2015.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |