Energy Performance Certificate

2a, Alpha Close, Bowers Gifford, SS13 2HZ

EPC Report

Energy rating

Current: 61 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 55 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 76 Potential: 76
Field Value
LMK KEY 8384-7222-1330-4909-3992
ADDRESS1 2a, Alpha Close
ADDRESS2 Bowers Gifford
ADDRESS3
POSTCODE SS13 2HZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-02-11
LOCAL AUTHORITY E07000066
CONSTITUENCY E14001154
COUNTY
LODGEMENT DATE 2014-02-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 215
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 6.8
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 151
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 1184
HEATING COST POTENTIAL 841
HOT WATER COST CURRENT 153
HOT WATER COST POTENTIAL 115
TOTAL FLOOR AREA 165
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 3
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 3% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2a, Alpha Close, Bowers Gifford
LOCAL AUTHORITY LABEL Basildon
CONSTITUENCY LABEL Castle Point
POSTTOWN BASILDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2014-02-11 17:42:02
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 38
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100090233269
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew