Energy Performance Certificate

34, Manning Road, WR9 8HW

EPC Report

Energy rating

Current: 54 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 47 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 72 Potential: 72
Field Value
LMK KEY 8383-6622-7690-4007-1926
ADDRESS1 34, Manning Road
ADDRESS2
ADDRESS3
POSTCODE WR9 8HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2017-02-23
LOCAL AUTHORITY E07000238
CONSTITUENCY E14001203
COUNTY
LODGEMENT DATE 2017-02-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 315
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 957
HEATING COST POTENTIAL 657
HOT WATER COST CURRENT 121
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 94
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 42
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 42% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34, Manning Road
LOCAL AUTHORITY LABEL Wychavon
CONSTITUENCY LABEL Droitwich and Evesham
POSTTOWN DROITWICH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-02-23 16:47:29
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100120683411
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display
Nation ew