Energy Performance Certificate

80, Tamar Close, PE27 3JE

EPC Report

Energy rating

Current: 54 E | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 47 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 82 Potential: 82
Field Value
LMK KEY 8375-7125-0030-2699-5996
ADDRESS1 80, Tamar Close
ADDRESS2
ADDRESS3
POSTCODE PE27 3JE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-05-11
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001298
COUNTY
LODGEMENT DATE 2015-05-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 331
ENERGY CONSUMPTION POTENTIAL 94
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 938
HEATING COST POTENTIAL 489
HOT WATER COST CURRENT 130
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 90
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 31
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 31% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.59
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 80, Tamar Close
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL Huntingdon
POSTTOWN ST. IVES
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2015-05-26 10:21:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100090120045
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew