Energy Performance Certificate

6, The Elms, Colyford, EX24 6QU

EPC Report

Energy rating

Current: 39 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 35 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 79 Potential: 79
Field Value
LMK KEY 8372-7023-0820-6080-2996
ADDRESS1 6, The Elms
ADDRESS2 Colyford
ADDRESS3
POSTCODE EX24 6QU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2012-07-10
LOCAL AUTHORITY E07000040
CONSTITUENCY E14001291
COUNTY
LODGEMENT DATE 2012-07-13
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 336
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 8.6
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 122
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 1270
HEATING COST POTENTIAL 560
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 133
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 91
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 7
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 7% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, The Elms, Colyford
LOCAL AUTHORITY LABEL East Devon
CONSTITUENCY LABEL Honiton and Sidmouth
POSTTOWN COLYTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2012-07-13 12:13:03
TENURE
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100040159844
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew