Energy Performance Certificate

59, Bincote Road, EN2 7RD

EPC Report

Energy rating

Current: 38 F | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 35 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 86 Potential: 86
Field Value
LMK KEY 8364-7927-2260-1054-9992
ADDRESS1 59, Bincote Road
ADDRESS2
ADDRESS3
POSTCODE EN2 7RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-03-14
LOCAL AUTHORITY E09000010
CONSTITUENCY E14001225
COUNTY
LODGEMENT DATE 2014-03-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 388
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 75
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 1219
HEATING COST POTENTIAL 454
HOT WATER COST CURRENT 310
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 102
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 20
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.59
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 59, Bincote Road
LOCAL AUTHORITY LABEL Enfield
CONSTITUENCY LABEL Enfield North
POSTTOWN ENFIELD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-03-17 08:07:30
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 207151579
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000007
Address display
Nation ew