Energy Performance Certificate

7, Fox Street, BB7 2AQ

EPC Report

Energy rating

Current: 32 F | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 3 | Potential: 27
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 3 Current: 3 27 Potential: 27
Field Value
LMK KEY 8363-7923-5840-9248-8992
ADDRESS1 7, Fox Street
ADDRESS2
ADDRESS3
POSTCODE BB7 2AQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-07-18
LOCAL AUTHORITY E07000124
CONSTITUENCY E14001422
COUNTY
LODGEMENT DATE 2017-07-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 3
ENVIRONMENT IMPACT POTENTIAL 27
ENERGY CONSUMPTION CURRENT 477
ENERGY CONSUMPTION POTENTIAL 233
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 176
CO2 EMISSIONS POTENTIAL 9.0
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1439
HEATING COST POTENTIAL 931
HOT WATER COST CURRENT 328
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 92
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, coal
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Fox Street
LOCAL AUTHORITY LABEL Ribble Valley
CONSTITUENCY LABEL Pendle and Clitheroe
POSTTOWN CLITHEROE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-07-19 11:22:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100010585357
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000002
Address display
Nation ew