Energy Performance Certificate

2 High Cedars The Drive, Farringdon, EX5 2JD

EPC Report

Energy rating

Current: 54 E | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 42 | Potential: 45
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 45 Potential: 45
Field Value
LMK KEY 8362-7220-0459-4222-0996
ADDRESS1 2 High Cedars The Drive
ADDRESS2 Farringdon
ADDRESS3
POSTCODE EX5 2JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-10-12
LOCAL AUTHORITY E07000040
CONSTITUENCY E14001232
COUNTY
LODGEMENT DATE 2012-10-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 45
ENERGY CONSUMPTION CURRENT 193
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 9.4
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 1627
HEATING COST POTENTIAL 1498
HOT WATER COST CURRENT 170
HOT WATER COST POTENTIAL 171
TOTAL FLOOR AREA 208
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 60
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 91
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 91% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 High Cedars The Drive, Farringdon
LOCAL AUTHORITY LABEL East Devon
CONSTITUENCY LABEL Exmouth and Exeter East
POSTTOWN EXETER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-10-12 11:14:13
TENURE Unknown
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 32
UPRN 10000248764
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew