Energy Performance Certificate

100a, Caulfield Road, E6 2EN

EPC Report

Energy rating

Current: 48 E | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 42 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 52 Potential: 52
Field Value
LMK KEY 8358-7526-5850-6848-3902
ADDRESS1 100a, Caulfield Road
ADDRESS2
ADDRESS3
POSTCODE E6 2EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-06-08
LOCAL AUTHORITY E09000025
CONSTITUENCY E14001213
COUNTY
LODGEMENT DATE 2018-06-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 396
ENERGY CONSUMPTION POTENTIAL 317
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 712
HEATING COST POTENTIAL 564
HOT WATER COST CURRENT 87
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 45
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.73
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 100a, Caulfield Road
LOCAL AUTHORITY LABEL Newham
CONSTITUENCY LABEL East Ham
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-06-10 03:28:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 46011928
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew