Energy Performance Certificate

5, Old Forge Close, Upper Dicker, BN27 3YJ

EPC Report

Energy rating

Current: 73 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 75 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 75 Potential: 75
Field Value
LMK KEY 8355-7036-3660-0797-4926
ADDRESS1 5, Old Forge Close
ADDRESS2 Upper Dicker
ADDRESS3
POSTCODE BN27 3YJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-06-23
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001330
COUNTY
LODGEMENT DATE 2015-06-23
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 158
ENERGY CONSUMPTION POTENTIAL 158
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 638
HEATING COST POTENTIAL 638
HOT WATER COST CURRENT 330
HOT WATER COST POTENTIAL 330
TOTAL FLOOR AREA 92
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.15 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.13 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 5, Old Forge Close, Upper Dicker
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL Lewes
POSTTOWN HAILSHAM
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2015-06-23 16:36:05
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 35
UPRN 10091054678
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display