Energy Performance Certificate

Flat 4, 8 Vernon Street, BL1 2PP

EPC Report

Energy rating

Current: 21 F | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 32 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 70 Potential: 70
Field Value
LMK KEY 8345-7526-3540-3652-2902
ADDRESS1 Flat 4
ADDRESS2 8 Vernon Street
ADDRESS3
POSTCODE BL1 2PP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2015-06-02
LOCAL AUTHORITY E08000001
CONSTITUENCY E14001110
COUNTY
LODGEMENT DATE 2015-06-04
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 960
ENERGY CONSUMPTION POTENTIAL 352
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 162
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 26
LIGHTING COST POTENTIAL 26
HEATING COST CURRENT 1073
HEATING COST POTENTIAL 361
HOT WATER COST CURRENT 126
HOT WATER COST POTENTIAL 51
TOTAL FLOOR AREA 26
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 4, 8 Vernon Street
LOCAL AUTHORITY LABEL Bolton
CONSTITUENCY LABEL Bolton North East
POSTTOWN BOLTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-06-04 12:28:02
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10001242827
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew