Energy Performance Certificate

1, Sandon Close, KT10 8JE

EPC Report

Energy rating

Current: 61 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 41 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 79 Potential: 79
Field Value
LMK KEY 8344-6422-4170-3850-7922
ADDRESS1 1, Sandon Close
ADDRESS2
ADDRESS3
POSTCODE KT10 8JE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-02-20
LOCAL AUTHORITY E07000207
CONSTITUENCY E14001230
COUNTY
LODGEMENT DATE 2014-02-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 293
ENERGY CONSUMPTION POTENTIAL 87
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 142
LIGHTING COST POTENTIAL 129
HEATING COST CURRENT 1780
HEATING COST POTENTIAL 930
HOT WATER COST CURRENT 153
HOT WATER COST POTENTIAL 123
TOTAL FLOOR AREA 255
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Temperature zone control
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Sandon Close
LOCAL AUTHORITY LABEL Elmbridge
CONSTITUENCY LABEL Esher and Walton
POSTTOWN ESHER
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2014-02-21 12:06:02
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100061318721
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew