Energy Performance Certificate

19 HARMONY ROAD, ROCHE, PL26 8ES

EPC Report

Energy rating

Current: 58 D | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 39 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 73 Potential: 73
Field Value
LMK KEY 8339-0324-2000-0089-5202
ADDRESS1 19 HARMONY ROAD
ADDRESS2 ROCHE
ADDRESS3
POSTCODE PL26 8ES
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2021-04-01
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001508
COUNTY
LODGEMENT DATE 2021-04-05
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 586
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 598
HEATING COST POTENTIAL 360
HOT WATER COST CURRENT 161
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 39
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19 HARMONY ROAD, ROCHE
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Austell and Newquay
POSTTOWN ROCHE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-04-05 09:20:42
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100040141486
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display
Nation ew