Energy Performance Certificate

23, Quarry Close, Handbridge, CH4 7LG

EPC Report

Energy rating

Current: 59 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 57 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 77 Potential: 77
Field Value
LMK KEY 8337-6324-9070-8126-6992
ADDRESS1 23, Quarry Close
ADDRESS2 Handbridge
ADDRESS3
POSTCODE CH4 7LG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2013-04-16
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001164
COUNTY
LODGEMENT DATE 2013-04-19
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 291
ENERGY CONSUMPTION POTENTIAL 157
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 38
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 502
HEATING COST POTENTIAL 290
HOT WATER COST CURRENT 158
HOT WATER COST POTENTIAL 110
TOTAL FLOOR AREA 57
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Quarry Close, Handbridge
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Chester South and Eddisbury
POSTTOWN CHESTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-04-19 14:28:47
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100010025060
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew