Energy Performance Certificate

54, The Green, Steeple Morden, SG8 0ND

EPC Report

Energy rating

Current: 27 F | Potential: 117 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 117 A Potential: 117 A

Environmental impact (CO₂)

Current: 4 | Potential: 130
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 4 Current: 4 130 Potential: 130
Field Value
LMK KEY 8336-7929-4080-4139-6922
ADDRESS1 54, The Green
ADDRESS2 Steeple Morden
ADDRESS3
POSTCODE SG8 0ND
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 117
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-01-21
LOCAL AUTHORITY E07000012
CONSTITUENCY E14001481
COUNTY
LODGEMENT DATE 2016-01-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 4
ENVIRONMENT IMPACT POTENTIAL 130
ENERGY CONSUMPTION CURRENT 582
ENERGY CONSUMPTION POTENTIAL -141
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 194
CO2 EMISSIONS POTENTIAL -2.3
LIGHTING COST CURRENT 39
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 1090
HEATING COST POTENTIAL 267
HOT WATER COST CURRENT 267
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, coal
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54, The Green, Steeple Morden
LOCAL AUTHORITY LABEL South Cambridgeshire
CONSTITUENCY LABEL South Cambridgeshire
POSTTOWN ROYSTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-01-21 16:41:23
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100090171200
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew