Energy Performance Certificate

2 Peacock Mews, North End, Raskelf, YO61 3LF

EPC Report

Energy rating

Current: 83 B | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 83 | Potential: 101
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 101 Potential: 101
Field Value
LMK KEY 8335-7839-4969-3087-8926
ADDRESS1 2 Peacock Mews
ADDRESS2 North End
ADDRESS3 Raskelf
POSTCODE YO61 3LF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE House
BUILT FORM
INSPECTION DATE 2015-11-23
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001582
COUNTY
LODGEMENT DATE 2015-11-27
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 101
ENERGY CONSUMPTION CURRENT 97
ENERGY CONSUMPTION POTENTIAL -9
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL -0.1
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 474
HEATING COST POTENTIAL 474
HOT WATER COST CURRENT 95
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 152
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.25 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2 Peacock Mews, North End, Raskelf
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Wetherby and Easingwold
POSTTOWN YORK
CONSTRUCTION AGE BAND 2014
LODGEMENT DATETIME 2015-11-27 15:41:26
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10070736504
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display