Energy Performance Certificate

12, Cannonthorpe Rise, Treeton, S60 5UN

EPC Report

Energy rating

Current: 60 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 51 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 77 Potential: 77
Field Value
LMK KEY 8335-7527-3050-3457-8922
ADDRESS1 12, Cannonthorpe Rise
ADDRESS2 Treeton
ADDRESS3
POSTCODE S60 5UN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-03-23
LOCAL AUTHORITY E08000018
CONSTITUENCY E14001452
COUNTY
LODGEMENT DATE 2015-03-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 269
ENERGY CONSUMPTION POTENTIAL 121
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 1029
HEATING COST POTENTIAL 661
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 124
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Cannonthorpe Rise, Treeton
LOCAL AUTHORITY LABEL Rotherham
CONSTITUENCY LABEL Rotherham
POSTTOWN ROTHERHAM
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2015-03-26 20:44:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 10000857035
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew